Basic Instructions
2
−
144
Outline
Performs AND operation by comparing two double word data items with
the comparison condition. The contact goes on or off depending on the
result of the comparison. The contacts are connected in series.
16
Program example
Ladder Diagram
Boolean
Ladder Diagram
Address
Instruction
Y30
0
D> =, DT 0, DT100
S1
S2
X0
0
1
10
ST
X
0
AND >=
DT
0
DT
100
OT
Y
30
S1
32-bit equivalent constant or lower 16-bit area of 32-bit data to be compared
S2
32-bit equivalent constant or lower 16-bit area of 32-bit data to be compared
Operands
Operand
Relay
Timer/Counter
Register
Index
register
Constant
Index
Operand
WX WY WR WL
(
*
1)
SV
EV
DT
LD
(
*
1)
FL
(
*
2)
IX
(
*
3)
IY
(
*
4)
K
H
Index
modifier
S1
A
A
A
A
A
A
A
A
A
A
N/A
A
A
A
S2
A
A
A
A
A
A
A
A
A
A
N/A
A
A
A
(
*
1) This cannot be used with the FP0/FP
−
e.
(
*
2) This cannot be used with the FP0/FP0R/FP
−
e/FP
Σ
/FP
−
X.
(
*
3) With the FP
Σ
, FP
−
X, FP0R, FP2, FP2SH, and FP10SH, this is I0 to IC.
(
*
4) With the FP
Σ
, FP
−
X, FP0R, FP2, FP2SH, and FP10SH, this is ID.
AND =
AND <>
AND >
AND >=
AND <
AND <=
32
−
bit data comparison:
AND equal
32
−
bit data comparison:
AND equal not
32
−
bit data comparison:
AND larger
32
−
bit data comparison:
AND equal or larger
32
−
bit data comparison:
AND smaller
32
−
bit data comparison:
AND equal or smaller
A: Available
N/A: Not Available
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...