High
−
level Instructions
3
−
621
Outline
These instructions determine the number of characters in a character
string.
With the FP0R/FP
Σ
/FP
−
X, the differential execution type instruction P259 (PLEN) cannot
be specified.
Program example
Ladder Diagram
Boolean
Ladder Diagram
Address
Instruction
10
F259 LEN, DT 0, DT 100
S
Trigger
R10
D
10
11
ST
R
10
F259
(LEN)
DT
0
DT
100
S
Character string
D
Area in which the coupled character strings are stored
Operands
Operand
Relay
Timer/Counter
Register
Index
register
Constant
Index
Operand
WX WY WR WL
SV
EV
DT LD
FL
(
*
1)
I
(
*
2)
K
H
f
M
Index
modifier
S
A
A
A
A
A
A
A
A
A
A
N/A N/A N/A N/A
A
D
A
A
A
A
A
A
A
A
A
A
N/A N/A N/A N/A
A
(
*
1) Cannot be specified with FP0R, FP
Σ
and FP
−
X.
(
*
2) I0 to ID
F259
P259
(PLEN)
(LEN)
Number of characters in a character string
A: Available
N/A: Not Available