Dual DSU-DP

Option Module & Plug-On Board

Option Module   PN 1200127L1#HS

Plug-On Board   PN 1200128L1

USER MANUAL

61200.128L1-1A
April 1996

Summary of Contents for 1200127L1

Page 1: ...DualDSU DP OptionModule Plug OnBoard OptionModule PN1200127L1 HS Plug OnBoard PN1200128L1 USERMANUAL 61200 128L1 1A April 1996...

Page 2: ...901 Explorer Boulevard P O Box 070020 Huntsville AL 35807 Phone 205 971 8000 Fax 205 971 8699 1996 ADTRAN Inc All rights reserved Printed in USA...

Page 3: ...ent Thisequipmentgenerates uses and can radiate radio frequency energy and if not installed and used in accordancewiththeinstructionmanual maycauseharmfulinterferencetoradio frequencies Operation of t...

Page 4: ...Table of Contents...

Page 5: ...d 7 Rear Panel 8 DTE Data Connection 9 Main DTE Data Connection Primary DTE 9 Configuration 11 Configuration Methods 12 AT Commands 12 V 25 bis Commands 13 SDLC Option 13 Character Format 13 Command S...

Page 6: ...5 Network Options 25 Network Rate 25 Network Address 27 Remote Configuration Option 28 Network Type 29 Configuring DTE Options 30 DTE Rate 30 Data Format 32 DTE Command Option 33 Transmit Clock 34 CS...

Page 7: ...Circuits 63 Local Unit Diagnostics 64 DTE and NET 65 Test Description 65 Test Purpose 65 Initiating 66 Interpreting Test Results 66 NET Only RT 67 Test Purpose 67 Initiating 67 Interpreting Test Resu...

Page 8: ...3 Appendix C DSU to Modem Interconnect 85 Modem Tail Circuit Application 85 Appendix D EIA 232 Connector 87 56 and 64 kbps Application 87 Appendix E DSU DP Configuration Menu Tree 89 Appendix F Troubl...

Page 9: ...lecting TR Options 42 Figure 4 13 Setting SR Options 43 Figure 4 14 Setting Test Timeout Option 44 Figure 4 15 Remote Digital Loopback 45 Figure 4 16 Editing Stored Phone Numbers 46 Figure 4 17 Enabli...

Page 10: ...AT Commands 34 Table 4 H CS Options AT Commands 37 Table 4 I Short and Long Delays at Different Operating Speeds 38 Table 4 J Anti Stream AT Commands 40 Table 4 K CD Options AT Commands 41 Table 4 L T...

Page 11: ...all rate DSU supporting services from 2 4 to 64 kbps including 19 2 and 38 4 kbps services The Dual DSU DP may be used in either point to point or multi point circuits The Dual DSU DP provides both V...

Page 12: ...D CD ALM TST RS CS TD RD CD ALM TST DSU III DBU DSU III DBU F DDS Network Router DSU III AR 56 kbps Router TSU HSU T1 ENTER ENTER 1 2 3 4 5 6 7 8 9 0 CANCEL CANCEL SHIFT SHIFT SHIFT SHIFT D A E B F C...

Page 13: ...nd 38 4 sync or async and 56 and 64 kbps sync only An additional rate of 57 6 kbps is available in async mode At the service rates of 56 kbps and 64 kbps the unit can be configured to run slower DTE r...

Page 14: ...Chapter 1 Introduction 4 Dual DSU DP User Manual 61200 128L1 1...

Page 15: ...container for use in shipping the Dual DSU DP for repair or for verification of damage during shipment Shipped by ADTRAN The following items are included in the ADTRAN ship ment The Dual DSU DP Option...

Page 16: ...ive of the action required for proper placement of the option module Perform the following steps to install the option module 1 Remove the cover plate from the TSU HSU unit rear panel 2 Slide the opti...

Page 17: ...o the opening in the option module back panel 3 Moving the plug on board downward secure the connection of the header pins at the front of the boards 4 Install two 4 40 screws at both front edges of t...

Page 18: ...faces via custom cables Pin assignments for the DTE connections are listed in the section DTE Data Connec tion in this chapter The DSU DP rear panel is shown in Figure 2 3 Figure 2 3 DSU DP Option Mo...

Page 19: ...clock option selected The DTE rate may be configured from the front panel or via the T Watch Management Program The DTE can operate in asynchronous or synchronous modes To prevent possible radio frequ...

Page 20: ...dy SR 8 F 109 Received Line Signal Detector CD 20 H Data Terminal Ready TR 17 J R 18 L L 11 R 104 Received Data RD A 12 T 104 Received Data RD B 24 V 115 Receiver Signal ElementTiming SCR A 25 X 115 R...