High
−
level Instructions
3
−
57
Outline
Skips to the
LBL
instruction with the same number as the data area
specified by the
F19 (SJP)
instruction.
20
Program example
Ladder Diagram
Boolean
Ladder Diagram
Address
Instruction
(LBL 20 )
R0
10
Label number
F19 SJP, DT 0
S
10
11
ST
R
0
F19
(SJP)
DT
0
S
16-bit area for storing the label number [0 to 255 (256 points)]
Operands
Operand
Relay
Timer/Counter
Register
Index
register
Constant
Index
Operand
WX WY WR WL
SV
EV
DT LD
FL
IX
(
*
1)
IY
(
*
2)
K
H
Index
modifier
S
A
A
A
A
A
A
A
A
A
N/A
N/A
N/A N/A
N/A
(
*
1) With the FP2, FP2SH, and FP10SH, this is I0 to IC.
(
*
2) With the FP2, FP2SH, and FP10SH, this is ID.
Explanation of example
Skips to the label number with the same number as the value in data register DT0 when trigger R0 turns on.
(LBL 1 )
R0
F19 SJP, DT 0
When
DT0 = K1
(LBL 125 )
When
DT0 = K125
Program
Program
When DT0 is K1, the program skips from
F19 (SJP)
to
LBL1
.
When DT0 is K125, the program skips from
F19 (SJP)
to
LBL125
.
F19
LBL
Auxiliary jump
(SJP)
Label
A: Available
N/A: Not Available
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...