High
−
level Instructions
3
−
486
2: For FP0 compatibility mode
Pulses are output using a duty of 25% fixedly. (The setting is invalid.)
The pulse output will start approx. 300us later after the direction output. (The
characteristics of a motor driver is considered.)
Application example
R0
F0 MV, H 22, DT 0
F0 MV, K1000, DT 1
F0 MV, K7000, DT 2
F0 MV, K300, DT 3
R1
F168 SPD1, DT 0, K 0
DT 0
H
00
22
DT 1
K 1000
DT 2
K 7000
DT 3
K
300
Flag conditions
・
Error flag (R9007): Turns on and stays on when:
・
Error flag (R9008): Turns on for an instant when:
−
The area specified using the index modifier exceeds the limit.
−
n is number except 0 and 1.
−
The value of S exceeds the limit of specified range.
−
S+1 is less than K40
−
S+1 > S+2
FP0/FP
−
e