1.2 Explanation of Relays
1 - 35
1.2.7
Timer (T)
Function of timers (T)
When a timer is activated and the set time elapses, the timer contact with the same
number as the timer turns on.
When the timer is in the time
−
up state and the timer execution condition turns off, the
timer contact turns off.
TM n
Tn
Timer number
Timer contact: on
Tn: on
n: Timer number
Time
−
up
Usage restrictions
When used as contacts, there are no restrictions on the number of times that can be
used.
For the FP2/FP2SH/FP10SH, if the Initialize/Test switch is set to the upper side (the
Initialize side) in the PROG mode, the timer contact goes off. If a hold type has been
specified, it goes off as well.
Note
With the FP2SH/FP10SH, system register 4 can be set in such a way
that the timer contact is not cleared even if the Initialize/Test switch is
set to the upper side.