background image

Manual-1

OPERATORS MANUAL

CP 52S

COMMERCIAL PROCESSOR

Quick Start

If you were the type that cheated on school book reports by just 

skimming through the reading assignments, then this section is 

for you! It gives you not quite enough information to 

really

 know 

what you’re doing. But, if you follow the recommended set up 

procedure, you should get at least a “B.”

Keep the amplifiers and the CP 52S turned 

off 

until all con-

nections are made.

PAGE INPUT

Connect the 

PAGING INPUT

 to the Euroblock on the rear 

panel. On the front, select the appropriate 

MIC 

or 

LINE 

switch 

position. Then set the gain with the 

INPUT TRIM

 control, 

then set the 

PAGING DETECT THRESHOLD

 and finally the 

PAGING LEVEL

MIC PHANTOM POWER

HIGH/LOW 

CUT FILTER

 and 

PAGE LEVEL TRACKS ZONE LEVEL

 

switches are located on the rear panel.

PROGRAM INPUTS

Connect line level program sources to the RCA 

PROGRAM 

INPUT

 jacks (

LINE L1

,

 L2

L3

 & 

PRIORITY)

. If you have a 

priority program, like a jukebox, connect it to the 

PRIORITY 

Input. The rear panel 

PRIORITY

 switch turns priority override 

ON 

or 

OFF

. The Priority program is automatically selected when 

signal is detected at its Input. Set the rear panel 

PROGRAM 

DETECT THRESHOLD

 and 

RELEASE TIME

 as desired.

WEAR PARTS:

 This product contains no wear parts.

LEVEL

4k

630

1.6k

40

100

250

PROGRAM

SELECT

OL

SIG

LIMIT

10k

PRIORITY

LIMIT

THRESHOLD

LIMIT

LEVEL

LINE 1

LINE 2

LINE 3

ACTIVE

INPUT

TRIM

OL

LINE

MIC

ON

OFF

DETECT

THRESHOLD

DUCKER

DEPTH

CP 52S

COMMERCIAL

PROCESSOR

POWER

ZONE

EQ

PROGRAM INPUT LEVELS

PAGING

LIMIT

THRESHOLD

REMOTE

L1

P

L2 L3

10

0

2

4

8

6

+60

+30

12

6

6

12

0

+

+8

–3

+20

–20

+16

+8

–3

+20

–20

+16

10

0

2

4

8

6

10

0

2

4

8

6

10

0

2

4

8

6

10

0

2

4

8

6

10

0

2

4

8

6

EXPAND OUTPUT

Wire the 

EXPAND OUTPUT

 Euroblock as required to a 

mono feed delivering 

PAGE

-only, 

PROGRAM

-only or 

ZONE

 

(both) signal depending on the switch setting. This Output uses 

a cross-coupled line driver and may be used balanced or unbal-

anced. Adjust the

 EXPAND OUTPUT LEVEL 

trim as desired. 

ZONE OUTPUT

The 

ZONE OUTPUT 

uses a cross-coupled line driver and 

may be used balanced or unbalanced. Set the front panel 

LIMIT 

THRESHOLD

 as required. Depress the rear panel 

MONO 

switch for a mono Zone.

ZR 1 REMOTE

You may use one 

ZR 1

 Remote (sold separately) with the 

CP 52S. Wire it to the 

ZONE REMOTE

 Euroblock as indi-

cated. If a ZR 1 remote is not used, any simple switch closure to 

ground will work for the 

D0 

and 

D1 

pins. These pins are TTL 

compatible (0 to 5 VDC). The logic is inverse Gray Code. Any 

ground referenced 5 volt DC control may be used as the input to 

Vc

. Do 

not

 ground the 

Vr

 pin.

READ ME

The CP 52S is 

very

 versatile. While this makes a large num-

ber of system applications possible, it also results in complexity. 

For this reason, it is 

important to use an organized approach for 

setup and calibration.

 A highly recommended setup procedure 

appears on page Manual-5. Please follow it to encounter fewer 

problems and reduce the need to increase our collective phone 

bills.

Summary of Contents for CP 52S

Page 1: ...3 ACTIVE INPUT TRIM OL LINE MIC ON OFF DETECT THRESHOLD DUCKER DEPTH CP 52S COMMERCIAL PROCESSOR POWER ZONE EQ PROGRAM INPUT LEVELS PAGING LIMIT THRESHOLD REMOTE L1 P L2 L3 10 0 2 4 8 6 60 30 12 6 6 12 0 8 3 20 20 16 8 3 20 20 16 10 0 2 4 8 6 10 0 2 4 8 6 10 0 2 4 8 6 10 0 2 4 8 6 10 0 2 4 8 6 EXPAND OUTPUT Wire the EXPAND OUTPUT Euroblock as required to a mono feed delivering PAGE only PROGRAM on...

Page 2: ...control of Zone Level and Zone Program Selection over to the Zone Remote Port Front panel ZONE LEVEL and ZONE PROGRAM SELECT controls are inactive when REMOTE is selected An optional wired ZR 1 remote may be connected to the Zone Remote Port An object smaller in diameter than the switch button is required to engage the REMOTE switch e ZONE LEVEL control adjusts the overall Level for the Zone Outpu...

Page 3: ...elivered to the ZONE EXPAND OUTPUT 0 EXPAND SOURCE switch assigns PAGE only PROGRAM only or full ZONE both as the source for the Expand Output q EXPAND OUTPUT features a balanced line driver with a Euroblock connector This mono Output may be wired balanced or unbalanced per the instructions in CP 52S Audio Connections on page Manual 4 w ZONE MONO switch when pressed in sums the left and right sign...

Page 4: ...earth or technical grounds If a unit is located far from the CP 52S or is of a type that might create grounding problems use isolation transformers When connecting any CP 52S Output as unbalanced use and ground leave floating Refer to the included RaneNote Sound System Interconnec tion for more information on proper wiring procedures current limited excess heat will be generated in the 5 volt supp...

Page 5: ...T THRESHOLD Min ccw Active front panel Paging LEVEL Min front panel LIMIT THRESHOLD 20 dBu front panel MIC PHANTOM POWER As required rear panel LOW HIGH CUT FILTER As required rear panel PAGE LEVEL TRACKS ZONE LEVEL OFF rear panel PROGRAM INPUT SETTINGS Input Levels Min front panel PRIORITY DETECT THRESHOLD Set to 50 dBu at factory range to 35 dBu rear panel PRIORITY RELEASE TIME Set to 12 sec at ...

Page 6: ...may gate on due to background sound 7 With an active Program source playing speak into the Paging mic Adjust the Paging LEVEL control to provide the correct Page to Program mix If the Paging Detect Threshold is set too high there may be a delay before speech is heard To correct this lower the Paging Detect Threshold setting 8 Set the Paging LIMIT THRESHOLD to limit the maximum Page level to the lo...

Reviews: