Recommended Calibration Procedure
The CP 52S is a very versatile instrument. While this allows it to conform to the requirements of a large number of system applica-
tions, it also results in complexity. For this reason, it is very important to use an organized approach to system calibration. Once the
system is connected and the internal switches set for your specific application, it is important to take the time for proper calibration.
The following is an ordered list of system adjustments that makes calibration easy and results in optimum performance.
This procedure assumes that a microphone is used for the Page. The procedure (except for the exact wording) is the same for other
Page sources.
Make sure the POWER is off!
PREFLIGHT CONTROL SETTINGS
PAGING SETTINGS:
• MIC/LINE Pad
As required
(front panel)
• INPUT TRIM
12:00 (center)
(front panel)
• DETECT THRESHOLD
Min (ccw, Active)
(front panel)
• Paging LEVEL
Min
(front panel)
• LIMIT THRESHOLD
+20 dBu
(front panel)
• MIC PHANTOM POWER
As required
(rear panel)
• LOW / HIGH CUT FILTER
As required
(rear panel)
• PAGE LEVEL TRACKS ZONE LEVEL OFF
(rear panel)
PROGRAM INPUT SETTINGS:
• Input Levels
Min
(front panel)
• PRIORITY DETECT THRESHOLD Set to -50 dBu at factory (range -∞ to -35 dBu; rear panel)
• PRIORITY RELEASE TIME
Set to 12 sec. at factory
(range 5 to 20 sec; rear panel)
• PRIORITY OFF / ON
OFF
(rear panel)
ZONE SETTINGS:
• DUCKER DEPTH
2:00 (about 15 dB)
(front panel)
• DUCKER OFF / ON
OFF
(front panel)
• PROGRAM SELECT
LINE 1, 2, 3 or P
(Any active Input; front panel)
• REMOTE
Out (local control)
(front panel)
• Zone LEVEL
Max
(front panel)
• LIMIT THRESHOLD
+20 dBu
(front panel)
• Equalizer
Flat
(front panel)
• Zone Output MONO
As required
(rear panel)
• Expand ZONE/PROGRAM/PAGE
As required
(rear panel)
SYSTEM CONNECTIONS
• Connect page microphone or line level paging source
• Connect Program sources
• Connect Output to amps
• Connect ZR 1 Remote control (if required)
...You are now ready to calibrate the CP 52S (
continued on next page...
)