background image

Manual-3

Rear Panel Description

1

 PAGING INPUT 

Euroblock connector may be wired per instructions in CP 52S Audio Connections on page Manual-4.

2

 MIC PHANTOM POWER

 switch, when ON, e15 volt Phantom Power to the PAGING INPUT connector. If the front 

panel LINE switch is selected, Phantom Power is defeated.

LOW / HIGH CUT FILTER

 switch, when IN, limits the bandwidth of the Paging Input from 100 Hz to 7 kHz, improving 

intelligibility in some installations. The Paging detector is always bandlimited to 100 Hz to 7 kHz.

PAGE LEVEL TRACKS ZONE LEVEL

 switch, when ON, forces the Paging level to track the Zone level. When OFF, Paging 

level and Zone level are independent.

Four 

PROGRAM INPUTS

 are provided. Three are non-priority Inputs — the fourth is a Program PRIORITY Input. When 

signal is detected at this Input, it is 

automatically

 selected as the Program Input source regardless of the front panel PROGRAM 

SELECT setting. 

6

 PRIORITY DETECT THRESHOLD 

control allows adjusting the threshold from -∞ (signal on) to -35 dBu (typ). The factory 

setting is -50 dBu. 

7

 PRIORITY OFF/ON

 switch allows disabling the automatic priority override function when in the OFF position. 

8

 PRIORITY RELEASE TIME

 control sets the delay time from last detected signal to release of automatic priority override. The 

range of control is 5 seconds (ccw) to 20 seconds (cw).

9

 EXPAND LEVEL 

trim adjusts the signal level delivered to the ZONE EXPAND OUTPUT.

EXPAND SOURCE switch

 assigns PAGE-only, PROGRAM-only or full ZONE (both) as the source for the Expand Output.

q

 

EXPAND OUTPUT

 features a balanced line driver with a Euroblock connector. This mono Output may be wired balanced or 

unbalanced per the instructions in CP 52S Audio Connections on page Manual-4.

ZONE MONO

 switch, when pressed 

in

, sums the left and right signals to provide a mono Zone signal available at both Left and 

Right Outputs.

e

 ZONE OUTPUT

 Port features a balanced line driver with a Euroblock connector. These Left and Right Outputs may be wired 

balanced or unbalanced per the instructions in CP 52S Audio Connections on page Manual-4. 

r

 ZONE REMOTE 

Port provides the wiring interface for the optional ZR 1 wired remote. The ZR 1 remote provides remote con-

trol of Zone Level and Zone Program Select functions. 

Refer to page Manual-4 for details.

Universal Voltage Input:

 via a miniature IEC 60320 C6 appliance inlet. This mates with an IEC 60320 C5 line cord (USA 

domestic). Do 

not

 lift the ground connection!

PRIORITY

3

2

1

RANE CORP. MADE IN U.S.A.

+

+

+

+

+

+

+

+

D1 D0

D1 D0

Vr Vc

Vr Vc

DETECT

THRESHOLD

RELEASE

SEC

CP 52S

PAGING INPUT

R

L

R

L

5

20

ZONE REMOTE

ZONE OUTPUT

MIN

MAX

PROGRAM INPUTS

RIGHT

LEFT

MONO

EXPAND

LEVEL

PROGRAM

LEVEL

OFF

ON

100-240 V

50/60 Hz 12 WATTS

ZONE PAGE

SOURCE

PROGRAM

THIS DEVICE COMPLIES WITH 

PART 15 OF THE FCC RULES FOR 

A CLASS 'B' COMPUTING DEVICE.

INPUT

LOW / HIGH

CUT

FILTER

PAGE LEVEL

TRACKS

ZONE LEVEL

MIC

PHANTOM

POWER

IN

OUT

OFF

ON

OFF

ON

100 Hz / 7 kHz

+15V

EXPAND OUTPUT

15

14

13

11

10

8 7 6

4

3

2

1

5

12

9

Summary of Contents for CP 52S

Page 1: ...3 ACTIVE INPUT TRIM OL LINE MIC ON OFF DETECT THRESHOLD DUCKER DEPTH CP 52S COMMERCIAL PROCESSOR POWER ZONE EQ PROGRAM INPUT LEVELS PAGING LIMIT THRESHOLD REMOTE L1 P L2 L3 10 0 2 4 8 6 60 30 12 6 6 12 0 8 3 20 20 16 8 3 20 20 16 10 0 2 4 8 6 10 0 2 4 8 6 10 0 2 4 8 6 10 0 2 4 8 6 10 0 2 4 8 6 EXPAND OUTPUT Wire the EXPAND OUTPUT Euroblock as required to a mono feed delivering PAGE only PROGRAM on...

Page 2: ...control of Zone Level and Zone Program Selection over to the Zone Remote Port Front panel ZONE LEVEL and ZONE PROGRAM SELECT controls are inactive when REMOTE is selected An optional wired ZR 1 remote may be connected to the Zone Remote Port An object smaller in diameter than the switch button is required to engage the REMOTE switch e ZONE LEVEL control adjusts the overall Level for the Zone Outpu...

Page 3: ...elivered to the ZONE EXPAND OUTPUT 0 EXPAND SOURCE switch assigns PAGE only PROGRAM only or full ZONE both as the source for the Expand Output q EXPAND OUTPUT features a balanced line driver with a Euroblock connector This mono Output may be wired balanced or unbalanced per the instructions in CP 52S Audio Connections on page Manual 4 w ZONE MONO switch when pressed in sums the left and right sign...

Page 4: ...earth or technical grounds If a unit is located far from the CP 52S or is of a type that might create grounding problems use isolation transformers When connecting any CP 52S Output as unbalanced use and ground leave floating Refer to the included RaneNote Sound System Interconnec tion for more information on proper wiring procedures current limited excess heat will be generated in the 5 volt supp...

Page 5: ...T THRESHOLD Min ccw Active front panel Paging LEVEL Min front panel LIMIT THRESHOLD 20 dBu front panel MIC PHANTOM POWER As required rear panel LOW HIGH CUT FILTER As required rear panel PAGE LEVEL TRACKS ZONE LEVEL OFF rear panel PROGRAM INPUT SETTINGS Input Levels Min front panel PRIORITY DETECT THRESHOLD Set to 50 dBu at factory range to 35 dBu rear panel PRIORITY RELEASE TIME Set to 12 sec at ...

Page 6: ...may gate on due to background sound 7 With an active Program source playing speak into the Paging mic Adjust the Paging LEVEL control to provide the correct Page to Program mix If the Paging Detect Threshold is set too high there may be a delay before speech is heard To correct this lower the Paging Detect Threshold setting 8 Set the Paging LIMIT THRESHOLD to limit the maximum Page level to the lo...