A - 63
A Appendix
GX-series EtherCAT Slave Unit User’s Manual
A-1 Obje
ct Diction
ary
A
A-1
-7 Manufa
ctur
er Specific Objects
*1
Command
is used to clear the IO-Link device backup data that is stored in the IO-Link Master Unit.
The meanings of the set values are as follows:
*2
Result
is used to display the cleared status of the IO-Link device backup data that is stored in the IO-Link Master Unit.
The meanings of the values are as follows:
320A hex
Message timeout for IO-Link device
Sub-index 0: Number of entries
Range:
−
Unit:
−
Default: 02 hex
Attribute:
−
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Sub-index 1: Session Timeout
Range: 00 to FF hex
Unit:
−
Default: 03 hex
Attribute: A
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
320B hex
*1
Digital Input Collection Setting
Sub-index 0: Number of entries
Range:
−
Unit:
−
Default: 08 hex
Attribute:
−
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Sub-index 1: Port 1 Digital Input Collection Setting
Range: 00 to 01 hex
Unit:
−
Default: 00 hex
Attribute: R
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Sub-index 2: Port 2 Digital Input Collection Setting
Range: 00 to 01 hex
Unit:
−
Default: 00 hex
Attribute: R
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Sub-index 3: Port 3 Digital Input Collection Setting
Range: 00 to 01 hex
Unit:
−
Default: 00 hex
Attribute: R
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Sub-index 4: Port 4 Digital Input Collection Setting
Range: 00 to 01 hex
Unit:
−
Default: 00 hex
Attribute: R
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Sub-index 5: Port 5 Digital Input Collection Setting
Range: 00 to 01 hex
Unit:
−
Default: 00 hex
Attribute: R
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Sub-index 6: Port 6 Digital Input Collection Setting
Range: 00 to 01 hex
Unit:
−
Default: 00 hex
Attribute: R
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Sub-index 7: Port 7 Digital Input Collection Setting
Range: 00 to 01 hex
Unit:
−
Default: 00 hex
Attribute: R
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Sub-index 8: Port 8 Digital Input Collection Setting
Range: 00 to 01 hex
Unit:
−
Default: 00 hex
Attribute: R
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Set value
Meaning
01 hex
Clears the IO-Link backup data.
00 hex
Does not clear the IO-Link backup data.
Set value
Meaning
0000 hex
Backup completed or not executed.
0001 hex
Backup failed.
FFFF hex
Execution is in progress.
Summary of Contents for GX-AD0471
Page 3: ...GX series EtherCAT Slave Units User s Manual Revised October 2018...
Page 4: ......
Page 42: ...2 EtherCAT Slave Unit 2 8 GX series EtherCAT Slave Unit User s Manual...
Page 66: ...4 Installation and Wiring 4 18 GX series EtherCAT Slave Unit User s Manual...
Page 84: ...5 EtherCAT Communications 5 18 GX series EtherCAT Slave Unit User s Manual...
Page 98: ...6 Basic Specifications of Slave Units 6 14 GX series EtherCAT Slave Unit User s Manual...
Page 178: ...7 Digital I O Slave Unit 7 80 GX series EtherCAT Slave Unit User s Manual...
Page 206: ...8 Analog I O Slave Unit 8 28 GX series EtherCAT Slave Unit User s Manual...
Page 280: ...11 Expansion Unit 11 20 GX series EtherCAT Slave Unit User s Manual...
Page 388: ...A Appendix A 84 GX series EtherCAT Slave Unit User s Manual...
Page 392: ...Revision 2 GX series EtherCAT Slave Unit User s Manual...
Page 393: ......