Error Messages and Troubleshooting
573
The error concerning
parallel interface was
detected.
Please turn off the
power supply, and
confirm the connection
of parallel interface.
Turn OFF the power and check the connection state of the parallel interface.
ProcItem error xxxx:
xxxxerror
This is displayed when the application software detects an abnormality.
Please contact one of our branches or regional offices as there may be a software
trouble.
Failed to paste. Please
check the save source
or the save destination.
No more scene can be added due to lack of memory.*
Review the inspection flow and reduce the memory consumption or switch to another
scene group.
*) The display varies depending on the controller.
The remaining capacity of the application is not sufficient for the FZ4-11
series.
The remaining data memory capacity is not sufficient for the FZ4-L35
/6
/7
series.
A camera outside the
guarantee is
connected.
A camera outside the guarantee is connected to the controller currently being used.
Destination folder is not
found. Please check.
Check the following points.
●
Have you deleted the destination folder?
●
For cases where he save destination is the folder in the USBDisk, is the USBDisk
connected to the controller? Or, has the USBDisk been detected?
PLC link error
PLC link cannot be established. Check the following points.
●
Are the FZ communication settings correct?
●
Are the PLC communication settings correct?
●
Is cable connected correctly?
Failed to register model
Search, classification, flexible search, shape , shape search II
Please register higher-contrast images as models.
Fine matching
For the fine matching, the 2 pixels at the edge of the image cannot be registered as the
model.
Available memory is
insufficient.
It may cause
insufficient memory
depending on the
setting.
Available application memory is low.
Memory may become insufficient during operation or an error may occur when the
operation mode is switched.
Review the inspection flow and reduce the memory consumption.
The free capacity of
RAMDisk is insufficient.
If nothing is done,
measurement cannot
be performed correctly.
Increase free capacity
in RAMDisk.
Clean up the content of RAMDisk to increase free space. If this error occurs even though
enough free space is available, scene group data may be too large. Review the
inspection flow.
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......