![background image](http://html1.mh-extra.com/html/omron/fz4-series/fz4-series_user-manual_1633222546.webp)
7
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
544
Controlling/Outputting through Parallel Communication
FZ4 User's Manual
When 1 line is used
Item
Description
Input format (DI7 to DI0)
Input example
Execute
(DI7)
Command
(DI6, DI5)
Command information
(DI4 to 0)
Continuous
measurement
Measure continuously
during input of
commands.
1
00
*****
The controller does not
detect this signal, so a
setting of either 0 or 1
makes no difference.
Input example:
10000000
Scene
switch
Switch measurement
scenes.
1
01
Input "Scene No." in
binary format. (0 to 31)
Switch to scene
2.
Input example:
10100010
Scene group
switch
Switch measurement
scene groups.
1
11
Input "Scene Group No."
in binary format. (0 to
31)
Switch to scene
group 2.
Input example:
11100010
Clearing
Measurement
Values
Clear measurement
values.
The OR signal and DO
signal are not cleared.
1
10
00000
Input example:
11000000
Clear Error
Clear error output.
The ERROR indicator is
also cleared.
1
10
00001
Input example:
11000001
Clear
Parallel
OR+DO
Clear the OR signal and
DO signal.
1
10
00010
Input example:
11000010
0: OFF 1: ON
Operation mode (FZ4-11
/H11
only) = [Multi-line random-trigger mode]
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......