FZ4 User's Manual
Controlling/Outputting through Parallel Communication
557
DI7
This is the trigger signal to clear the OR and DO signal.
After DI0 to 6 is set, turn DI7 ON after an interval over 1 ms. After checking that the OR or DO signal
has turned OFF, turn DI7 OFF, and then turn DI0 to 6 OFF.
Clears error by the parallel command
Output signal
Signal
Function
RUN
Turns ON when the controller is set to the RUN window. Turns OFF in the ADJUST window.
READY
This does not change when an error is being cleared.
Do not, however, clear the error signal when the READY signal is turned OFF. The command will
not be executed correctly.
BUSY
This does not change when an error is being cleared.
Do not, however, clear an error when the BUSY signal is turned ON. The command will not be
executed correctly.
OR
This does not change when an error is being cleared.
DO0 to 15
This does not change when an error is being cleared.
GATE
This does not change when an error is being cleared.
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......