6
Changing
the
System
Environment
350
Setting the System Operation Environment
FZ4 User's Manual
Item
Setting value
[Factory default]
Description
Serial
(Ethernet)
●
[Normal(UDP)]
●
Normal(TCP)
●
Normal(TCP Client)
●
Normal(UDP)
(Fxxx series method)
●
PLC Link
(SYSMAC CS/CJ/CP/One)
●
PLC Link
(MELSEC QnU/Q/QnAS)
●
PLC Link
(JEPMC MP)
Specifies the communication module.
Serial/Ethernet
Normal/Normal (Fxxx series method):
Communication is performed with external devices
through Normal communication. For differences
between Normal and Normal (Fxxx series method),
see the following Reference.
PLC Link: Communication is performed via a link
area with the PLC.
Parallel
Standard Parallel I/O: Communication is performed
via a standard parallel interface.
Fieldbus: Communication is performed via
EtherCAT communication and EtherNet/IP.
EtherCAT is valid only when FZM1 controller is
used.
Remote operation: The controller is operated from
an external device.
Serial
(RS-232C/
RS-422)
●
[Normal]
●
Normal
(Fxxx series method)
●
PLC Link
(SYSMAC CS/CJ/CP/One)
●
PLC Link
(MELSEC QnU/Q/QnAS)
Parallel
[Standard Parallel I/O]
Specifies the communication module.
Serial/Ethernet
Normal/Normal (Fxxx series method):
Communication is performed with external devices
through Normal communication. For differences
between Normal and Normal (Fxxx series method),
see the following Reference.
PLC Link: Communication is performed via a link
area with the PLC.
Parallel
Standard Parallel I/O: Communication is performed
via a standard parallel interface.
Fieldbus: Communication is performed via
EtherCAT communication and EtherNet/IP.
EtherCAT is valid only when FZM1 controller is
used.
Remote operation: The controller is operated from
an external device.
Fildbus
●
[OFF]
●
EtherCAT
●
EtherNet/IP
Remote
Operation
●
[ON]
●
OFF
Important
●
Do not set EtherNet/IP and PLC link at the same time. They cannot be used at the same time.
Example)
SetSerial (Ethernet): PLC link and Fieldbus: EtherNet/IP at the same time.
Set Serial (RS-232C/422): PLC link and Fieldbus: EtherNet/IP at the same time.
Set PLC link and Fieldbus: EtherNet/IP at the same time to both serial (Ethernet) and serial (RS-232C/
422).
●
Do not set PLC link to both serial (Ethernet) and serial (RS-232C/422). They cannot be used at the
same time.
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......