Tool
118
Using NG Analyser
FZ4 User's Manual
9.
Repeat steps 5 to 8 to correct the setting values corresponding to all causes of false judgement.
10.
Select [Execute batch measurement] to confirm that no images are falsely judged.
If there are still falsely judged images, repeat the same procedure until a re-measurement finds
no falsely judged images.
Note
●
OK/NG judgements can be changed by using [Send to OK folder] and [Send to NG folder] buttons. In this case,
the changes will not be reflected until re-measurement is performed.