Communicating through Serial Communication (PLC Link)
371
Address
0 to 99999
[100]
Set the top channel address in the
Response area.
Data output area
Area
●
[CIO Area (CIO)]
●
Work Area(WR)
●
Holding Bit Area(HR)
●
Auxiliary Bit Area (AR)
●
DM Area (DM)
●
EM Area(EMO)
Set the Data output area.
Address
0 to 99999
[200]
Set the top channel address in the
Data output area.
Output control
●
None
●
[Handshaking]
Set whether or not to provide an
interlock with the PLC when performing
data output.
None: Data is output regardless of the
status of signals from the PLC. GATE
is always OFF.
Handshaking: Data is output after
confirming DSA from the PLC.
Retry interval [ms]
1000 to 999999
[10000]
Set the communication retry interval.