![background image](http://html1.mh-extra.com/html/omron/fz4-series/fz4-series_user-manual_1633222550.webp)
7
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
548
Controlling/Outputting through Parallel Communication
FZ4 User's Manual
Example 2) If there is a process after a [Parallel judgement output]
Output signal
Signal
Function
RUN
Turns on when the controller is available for measurement and the RUN window is displayed. It is
OFF in the ADJUST window, so switch to the RUN window during operation.
BUSY
Indicates that controller is currently measuring or switching the scene. Do not input next command
while the BUSY signal is on. Otherwise, on-going processing or commands that are input will not be
performed correctly.
OR
Outputs overall judgement. This is determined when the measurement is completed (BUSY signal
ON
→
OFF).
Selection of whether ON occurs during an OK judgement result or NG judgement result can be
performed in the communication specifications settings window.
Reference:
Setting Communication Specifications (Parallel Interface) (p.540)
DO
Outputs the results for expressions set in the processing item [Parallel Judgement Output]/[Parallel
Data Output].
Selection of whether ON occurs during an OK judgement result or NG judgement result can be
performed in the communication specifications settings window.
Reference:
Setting Communication Specifications (Parallel Interface) (p.540)
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......