![background image](http://html1.mh-extra.com/html/omron/fz4-series/fz4-series_user-manual_1633222305.webp)
4
Using
Tool
FZ4 User's Manual
Using Custom Command
303
System data
Identification
Meaning
Initial value
rsMode
Interface
0: RS-232C
1: RS-422
0
baudRate
Baud rate[bps]
38400
byteSize
Data length[bit]
7 or 8
8
parity
parity
0:none
1:odd number
2:even number
0
stopBits
stop bits[bit]
0:1
1:2
0
softFlow
Flow control
0:None
1:Xon/Xoff
0
delimiter
Delimiter
0:CR
1:LF
2:CR+LF
0
timeout
Timeout[s]
5
Supported functions
IoInitialize
○
GetPort
○
Input terminal a point input (p.214)
PutPort
○
Output terminal a point output (p.250)
BusyOut
×
-
JudgeOut
×
-
RunOut
×
-
GetAll
○
Input terminal all point input (p.210)
PutAll
○
Output terminal all point output (p.249)
ReceiveData
○
SendData
○
SendString
○
ReadPlcMemory
×
-
WritePlcMemory
×
-
SetPlcData
×
-
GetPlcData
×
-
Example
Receive data
A parameter of ReceiveData, the parameter size are unnecessary.
Dim data&(256)
'Gets the five data.
ReceiveData "SerialPlcLink", data&(), 4*5, size&
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......