6
Changing
the
System
Environment
FZ4 User's Manual
Setting Conditions for Camera Use
343
Note
●
The STGOUT pulse width is set in "Electronic flash setting" of the [Camera Image Input] processing item.
Reference:
"Processing Item List Manual", "Electronic Flash Setting" (p.24)
1.
On the Main screen, tap the [System] menu - [Camera] - [Inter-camera setting].
The Inter-camera Setting window is displayed.
2.
Tap [...] of each item and set values.
Item
Set value
[Factory default]
Description
STEP - Camera 0 delay
[0] to 511
(1 count/30 μs)
Max. 15 ms
Set delay between receiving the STEP signal
and the beginning of camera exposure.
Delay time
= count x 30 μs + 122 μs
STEP - Camera 1 delay
STEP - Camera 2 delay
STEP - Camera 3 delay
3.
Tap [OK].
The settings are confirmed and the Inter-camera Setting window closes.