4
Using
Tool
FZ4 User's Manual
Using Custom Command
153
9
Function
name
Display and edit function name for selected comand.
10
Comment
Display and edit comment for selected comand.
11
Enable/
Disable
Set/display whether custom command is enabled.
If defined but not checked, it is not executed.
12
Busy On
Set/display whether to change to measurement stop state
(MeasureStop) before executing command. If checked, BUSY is
turned ON while command is executing, and then after execution of
command has finished, measurement stop state is released
(MeasureStart). Afterwards, a MeasureInit event is raised.
14
Export
Export the macro program to file.
15
Import
Import the macro program from file.
The existing data will be overwritten.
2.
Select the command number to be registered.
3.
Enter the command name, function name and comment.
Setting item
Description
Command
name
Specify Non-procedure command identification name.
Function
name
Set when using created command as function in other command.
Comment
Maximum 256 characters
Busy On
Set whether to change to measurement stop state (MeasureStop) before executing
command. If checked, BUSY is turned ON while command is executing, and then
after execution of command has finished, a MeasureInit event is raised.
4.
Tap the [Edit] button.
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......