Communicating through Serial Communication (PLC Link)
369
2.
In the communication setting area, set the following items.
Setting item
Setting value
[Factory default]
Description
Interface
●
[RS-232C]
●
RS-422
[Note 3]
Adjust to the PLC communication specifications.
When connecting with PLC made by OMRON, set "Upper Link"
on the PLC side.
Band rate
[bps]
[Note 1]
●
2400
●
4800
●
[9600]
●
19200
●
38400
●
57600
●
115200
Adjust to the PLC communication specifications.
Data length
[bit]
[Note 2]
●
[7]
●
8
Adjust to the PLC communication specifications.
Parity
●
None
●
Odd
●
[Even]
Stop bit [bit]
●
1
●
[2]
Flow control
[None]
Flow control is not performed with software.
If the time in which there is no response from external devices
reaches the timeout setting time, a timeout error occurs and an
error message is displayed in the window. The parallel
interface ERROR signal also turns on.
Xon/Xoff
Flow control is performed with software. Data is sent according
to the Xon/Xoff codes from external devices.
Timeout [s]
1 to 120
[5]
Set the time in which a timeout error will occur in seconds.
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......