![background image](http://html1.mh-extra.com/html/omron/fz4-series/fz4-series_user-manual_1633222528.webp)
7
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
526
Control/Output through EtherNet/IP
FZ4 User's Manual
+4
CMD-PARAM
Command
parameter
(Maximum
6CH)
+5
+6
+7
+8
+9
Signal
Signal name
Function
EXE
Command execution bit
Executes commands
Reference:
Command Control (EtherNet/IP) (p.532)
DSA
Data output request bit
Requests the next data output
Reference:
Data Output (EtherNet/IP) (p.535)
XEXE
Measuring command execution bit
Executes a measuring command
CMD-CODE
Command code
Stores command codes
CMD-PARAM Command parameter
Stores command parameters
For input connections, execution results and output data from the controller are set. Execution results
from the controller (control outputs, command codes, response codes, response data) are output to the
response area, while output data from the controller are output to the data output area.
Input connection
Originator
←
Target (FZ4)
Response area
top channel
Bit
Name
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
+0
XWAIT XBUSY XFLG
RUN OR
BUSY FLG
Control output
(2CH)
+1
GATE
+2
CMD-CODE
Command code
(2CH)
+3
+4
RES-CODE
Response code
(2CH)
+5
+6
RES-DATA
Response data
(2CH)
+7
+8
DATA0
Output data 0
+9
+10
DATA1
Output data 1
+11
+12
DATA2
Output data 2
+13
+14
DATA3
Output data 3
+15
+16
DATA4
Output data 4
+17
+18
DATA5
Output data 5
+19
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......