4
Using
Tool
FZ4 User's Manual
Using Custom Command
271
Set the output mode of the measurement result
SetMeasureOut <mode>
Parameters
<mode>
Output mode (0: OFF, 1: ON) (integer type)
Return Value
None.
Description
Set the output mode of the measurement result.
When set an output mode to 0, the data are not output to the outside even if the serial data output in the
flow is carried out.
When I set an output mode to 1, the data are output to the outside if the serial data output in the flow is
carried out.
Example
Turn on an output mode.
SetMeasureOut 1
Set PLC the write data
SetPlcData <ioIdent>, <writeData()>, <offset>, <size>, <data>
Parameters
<ioIdent>
Identification name of I/O module (character type)
<writeData()>
Write data(integer type Sequence)
<offset>
Offset value (integer type)
<size>
Size of write data (integer type)
<data>
Data which are targeted for setting (any type)
Return Value
None.