7
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
FZ4 User's Manual
Communicating through Serial Communication (PLC Link)
429
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Saving all data
The scene group 0 data currently being used by the controller is saved to a file.
Command (PLC to controller)
Command
area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
5000
0101
0000
0000
0000
Sets command codes.
+3
0070
0000
0000
0111
0000
+4
―
0000
0000
0000
0000
[Destination]
Up to 256 characters
+5
―
0000
0000
0000
0000
Response (Controller to PLC)
Response
area
top channel
Bit
Description
15-12
11-8
7-4
3-0
+2
0101
0000
0000
0000
Command code
Store response target command codes.
+3
0000
0000
0111
0000
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Screen capture
Captures the screen. The folder into which the captured image is saved depends on the system data
setting. Saves with the file name in the argument. If the file name extension is other than ".bmp", then
".bmp" is added to the file name.
Command (PLC to controller)
Command
area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
6010
0110
0000
0001
0000
Sets command codes.
+3
0070
0000
0000
0111
0000
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......