FZ4 User's Manual
Controlling/Outputting through Parallel Communication
545
Item
Description
Input format (DI7 to DI0)
Input example
Execute
(DI7)
Command
(DI6, DI5)
Line No.
(DI4)
Command
information
(DI3 to 0)
Continuous
measurement
Measure
continuously
during input of
commands.
1
00
0 or 1
Specify the
line number
to send
commands
to.
*****
The controller
does not see
this signal, so
a setting of
either 0 or 1
makes no
difference.
Continuously measure
line 1
Input example:
10010000
Scene
switch
Switch
measurement
scenes.
1
01
Input "Scene
No." in binary
format. (0 to
15)
Switch line 0 to Scene
2
Input example:
10100010
Scene group
switch
Switch
measurement
scene groups.
1
11
Input "Scene
Group No." in
binary format.
(0 to 15)
Switch line 1 to Scene
Group 2
Input example:
11110010
Clearing
Measurement
Values
Clear
measurement
values.
The OR signal
and DO signal
are not cleared.
1
10
0000
Clear the
measurement values
of line 1
Input
example:11010000
Clear Error
Clear error
output.
The ERROR
indicator is also
cleared.
1
10
0001
Clear the error of line
0
Input example:
11010001
Clear
Parallel
OR+DO
Clear the OR
signal and DO
signal.
1
10
0010
Clear the OR signal
and DO signal of line 1
Input example:
11010010
0: OFF 1: ON
Reference
●
When the input command is not received correctly, the ERROR signal turns on.
Important
●
When parallel continuous measurement is engaged and continuous STEP signal is input, switching of scene
group should be avoided. When this is performed, set "Unchecked" in "Save scene group on switch scene" in
either of the settings items below.
●
Switch Scene Group window Reference:
●
[Measure setting] in the [Measure] menu Reference:
Setting Conditions Related to Operation during Measurement (p.344)
Output Format
Each time measurement is performed, the measurement result is output.
Output can be selected to turn on either when the judgement result is OK or when it is NG. The factory
default setting is "ON at NG".
Reference:
Setting Communication Specifications (Parallel Interface) (p.540)
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......