4
Using
Tool
FZ4 User's Manual
Using Custom Command
213
Example
Gets the setting information of image display window 3.
GetImageWindow 3, locationX&, locationY&, width&, height&, unitNo&, subNo&, magnification#, originX&,
originY&, update&, visible&
Gets measurement result the Output presence
GetMeasureOut
Parameters
Return Value
Returns the value of the integer type.
The content of the value is Output presence measurement result. (0: no output, 1: output)
Description
Gets measurement and the Output presence.
If an acquisition value carries out the serial data output in the case of 0, the data are not output to the
outside.
If an acquisition value carries out the serial data output in the case of 1, the data are output to the
outside.
Example
An acquisition value sets an initial value for output data at the time of 0.
*outputsub
output& = GetMeasureOut
If output& = 0 Then
outdataA& = 0
outdataB& = 0
outdataC& = 0
Else
outdataA& = 100
outdataB& = 200
outdataC& = 300
Endif
End sub
Gets PLC the read data
GetPlcData <ioIdent>, <readData()>, <offset>, <size>, <data>
Parameters
<ioIdent>
Identification name of I/O module (character type)
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......