3
Performing
Test
Measurement/Starting
Operation
98
Useful Functions for Operation
FZ4 User's Manual
Switch
saving folder
by judge
●
Checked
●
[Unchecked]
If checked, OK/NG folders are automatically created and image
files are divided by scene and saved.
"Save to file" setting example and save destination
Example of setting
Destination
●
Folder name: USBDisk
●
Prefix: image_
●
"Switch saving folder by scene":
Checked
●
"Switch saving folder by judge":
Checked
Saving will be performed as follows for the settings
example on the left
●
OK image save destination:
\USBDisk\S000-000\OK\image_(Measurement ID).IFZ
●
NG image save destination:
\USBDisk\S000-002\NG\image_(Measurement ID).IFZ
4.
Set the image logging priority conditions.
This setting is only valid when "Save to file" is selected in the image logging saving
conditions.
When the measurement takt time is short, time lag may occur with writing from the controller
memory to the RAMDisk or USBDisk and temporary absences of free capacity in the controller
memory may occur. Select whether logging or measurement has priority at these times.
Setting item
Setting
value
[Factory
default]
Description
Logging
priority
[Logging]
When there is no free capacity in the controller memory, subsequent
measurement cannot be received until free capacity becomes
available.
All measurement target images are logged, but the measurement takt
time becomes longer.
Measurement
Measurement will continue even if there is no free capacity in the
controller memory. New logging is not performed until free capacity
becomes available in the controller memory.
The measurement takt time is maintained, but some measurement
may not be logged.
5.
Set the data logging conditions.
The data format is set with the processing item "Data Logging".
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......