![background image](http://html1.mh-extra.com/html/omron/fz4-series/fz4-series_user-manual_1633222306.webp)
4
Using
Tool
304
Using Custom Command
FZ4 User's Manual
Send data
A parameter of ReceiveData, the parameter size are unnecessary.
Dim data&(256)
'Transmit the five data.
SendData "SerialPlcLink", data&(), 4*5
SerialPlcLinkM
Serial Interface PLC Link (MELSEC QnU/Q/QnAS) communication
IoModule identification name
SerialPlcLinkM
Overview
This is a module is for sending and receiving commands and data via the serial PLC Link interface.
System data
Identification
Meaning
Initial value
rsMode
Interface
0: RS-232C
1: RS-422
0
baudRate
baud rate[bps]
9600
byteSize
Data length [bit]
7 or 8
7
parity
Parity
0:none
1:odd number
2:even number
2
stopBits
Stop bits [bit]
0:1
1:2
1
softFlow
Flow control
0:none
1:Xon/Xoff
0
timeout
timeout[s]
5
PLC Link data
Identification
Meaning
Initial value
commandArea
Command area Area
Data register
commandMemoryAddress
Command area Address
0
responseArea
Response area Area
Data register
responseMemoryAddress
Response area Address
100
outputArea
Data Output area Area
Data register
outputMemoryAddress
Data Output area Address
200
handshake
handshaking
1
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......