What’s In The Box

One (1) Prime Chime Plus

Two (2) Lighted Doorbell Buttons

Prime Chime Plus

INSTALLATION INSTRUCTIONS

Model: 

PRCP2

Tools Needed

The Prime Chime Plus requires very few tools for installation. A screwdriver and a pair of wirecutters will be 
required to install the chime.

WARNING - RISK OF SHOCK

1. This fixture is to be installed by only a qualified electrician.
2. This fixture is to be used at 120V AC/60Hz power supply only.
3. This fixture is designed for use in a circuit protected by a fuse or circuit breaker.
4. Turn off the power supply at the fuse or circuit breaker box before you install this fixture.
5. Turn off the power supply again when you perform maintenance.
6. Double check all connections to be sure they are all tight and correct.
7. Operation environment: to be installed indoors under dry and ventilated environment. It should NOT be installed damp locations or           

environment with high temperature. Installation of this fixture should be kept away from other electrical devices.

One (1) Hardware Pack

Junction Box

Pre-install a dual voltage box (CARLON Model#SC200DV or equivalent, not provided) before installation of this device.

Video Doorbell Compatibility Notes

For all video doorbells: 
1) To ensure proper operation of the PRCP2, no more than one video doorbell should be attached (Front Door or Back Door)
2) Make sure the video doorbell is fully charged prior to installation. Low battery levels may cause abnormal performance of the PRCP2.
3) Wiring must not exceed the following: 70’ from doorbell to first unit. 200’ total length if installing more than one PRCP2

For Ring products: 
1) Adjust the “Ring tone length” in the App to 2 seconds to avoid multiple chime cycles  (see Ring instructions for details).
2) The Ring Power Kit (diode) should not be installed when using the NICOR PRCP2

Summary of Contents for Prime Chime Plus

Page 1: ... they are all tight and correct 7 Operation environment to be installed indoors under dry and ventilated environment It should NOT be installed damp locations or environment with high temperature Installation of this fixture should be kept away from other electrical devices One 1 Hardware Pack Junction Box Pre install a dual voltage box CARLON Model SC200DV or equivalent not provided before instal...

Page 2: ...nting tube Attach doorbell button to chime wiring using screw terminals Insert button mounting springs into tube and push against surface Replacement Remove existing stucco button Reattach wiring to PRCP2 compatible stucco button and insert into existing tube For Standard or Decorator Buttons Attach doorbell button to chime wiring 18ga or 22ga using screw terminals and mount doorbell button to sur...

Page 3: ... greater at each unit per the diagram 2 Connect low voltage bell wires 18ga or 22ga into the first unit into ports 1 and 2 3 Junction Box Black Line Black Line White Neutral White Neutral 120V 60Hz only Run bell wiring from ports 3 and 4 of the first unit into ports 1 and 2 of the next unit max 2 units Leave ports 3 and 4 of the last unit open Note Maintain poliarity to avoid unit damage 1 to 3 an...

Page 4: ...vice pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference wi...

Reviews: