background image

1

MEUEN-EX10 V2.0

Thank you for purchasing products from Panasonic Electric Works SUNX

Co., Ltd. Please read this Instruction Manual carefully and thoroughly for

the correct and optimum use of this product. Kindly keep this manual in a

convenient place for quick reference.

This product has been developed / produced for industrial use only.

For the convergent reflective type EX-14

, maintain adequate distance

from reflective objects in the background, e.g. conveyors, since they may

adversely effect sensing. 

A thin 0.1mm

2

 cable is used for this product. Do not use excessive force

when pulling on the cable: it may cause cable to break.

Make sure that the power supply is off while wiring.

Incorrect wiring will damage the sensor.

Verify that the supply voltage including the ripple is within the rating.

Verify that the supply voltage variation is within the rating.

If power is supplied from a commercial switching regulator, ensure that

the frame ground (F.G.) terminal of the power supply is connected to an

actual ground.

In case noise generating equipment (switching regulator, inverter motor,

etc.) is used in the vicinity of this product, connect the frame ground

(F.G.) terminal of the equipment to an actual ground.

Do not run the wires together with high-voltage lines or power lines or put

them in the same raceway. This can cause malfunction due to induction.

You can extend the cable up to 50m max. with 0.3mm

2

 or more cable for

both emitter and receiver. However, in order to reduce noise, make the

wiring as short as possible.

Do not use during the initial transient time (0.5s) after the power supply is

switched on.

Ensure that the sensor is not directly exposed to the following light

sources as they may adversely effect sensing performance: fluorescent

light from a rapid-starter lamp, a high frequency lighting device, sunlight

etc.

This sensor is suitable for indoor use only.

Avoid dust, dirt and steam. Do not use this sensor in places having

excessive vapor, dust, etc., or where it may come in direct contact with

corrosive gas.

Take care that the sensor does not come in contact with oil, grease,

organic solvents such as thinner, etc., strong acid, or alkalines.

Do not apply stress directly to the sensor cable joint by forcibly bending
or pulling.

Since the cable end is not waterproof, do not use the sensor in an

application where water could seep in from the cable end.

The tightening torque should be 0.2N·m or less.

Mounting using tapped holes

Side sensing

Front sensing

When using the attached screws and nuts

Side sensing

Front sensing

INSTRUCTION MANUAL

Photoelectric Sensor

Ultra-slim type

EX-10

 Series

WARNING

• Never use this product as a sensing device for personnel protection.

• In case of using sensing devices for personnel protection, use 

products which meet laws and standards, such as OSHA, ANSI or IEC 

etc., for personnel protection applicable in each region or country.

1

CAUTIONS

2

MOUNTING

11mm

M2 x 0.4mm ø

10mm M2

6mm

Sensing direction

11mm

M2 x 0.4mm ø

7mm

8mm M2

Sensing direction

11mm

10mm M2

Thickness of mounting plate: 2mm or less

Flat washers

Spring washers

Sensing direction

11mm

8mm M2

Thickness of mounting plate: 2.5mm or less

Sensing direction

Flat washers

Spring washers

Rugghölzli 2

CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Reviews: