background image

1

MEUEN-EX20 V2.0

Thank you for purchasing products from Panasonic Electric Works SUNX
Co., Ltd. Please read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep this manual in a
convenient place for quick reference.

This product has been developed / produced for industrial use only.

A thin 0.1mm

2

 cable is used for this product. Do not use excessive force

when pulling on the cable: it may cause cable to break.

EX-24

(-PN) types are not incorporated with a sensitivity adjuster.

Maintain adequate distance from reflective objects in the background,
e.g. conveyors, since they may adversely effect sensing.

If a reflective object is present in the background, the sensing of
EX-28

A(-PN) may be affected. When setting up the sensor, confirm

that the reflective object has no effect. If the reflective object affects
sensing, removing the reflective object, color it black, or take other
appropriate measures.

If sensors are mounted close together and the ambient temperature is
near the maximum rated value, provide for enough heat radiation /
ventilation.

Make sure that the power supply is off while wiring.

Incorrect wiring will damage the sensor.

Verify that the supply voltage including the ripple is within the rating.
Verify that the supply voltage variation is within the rating.

If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an
actual ground.

In case noise generating equipment (switching regulator, inverter motor,
etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.

Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.

You can extend the cable up to 50m max. with 0.3mm

2

 or more cable for

both emitter and receiver (thru-beam types). However, in order to reduce
noise, make the wiring as short as possible.

Do not use during the initial transient time (0.5s) after the power supply is
switched on.

Ensure that the sensor is not directly exposed to the following light
sources as they may adversely effect sensing performance: fluorescent
light from a rapid-starter lamp, a high frequency lighting device, sunlight
etc.

Do not apply stress directly to the sensor cable joint by forcibly bending
or pulling.

This sensor is suitable for indoor use only.

Avoid dust, dirt and steam. Do not use this sensor in places having
excessive vapor, dust, etc., or where it may come in direct contact with
water or corrosive gas.

Take care that the sensor does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid, or alkalines.

EX-21

EX-23

INSTRUCTION MANUAL

Photoelectric Sensor

Ultra-compact type

EX-20

 Series

WARNING

• Never use this product as a sensing device for personnel protection.
• In case of using sensing devices for personnel protection, use 

products which meet laws and standards, such as OSHA, ANSI or IEC 
etc., for personnel protection applicable in each region or country.

1

CAUTIONS

2

PART DESCRIPTION

No.

Part

Description

1

Beam axis

2

Stability indicator 
(green)

Receiver only.

Lit when detection is stable according 
to the parameters set.

3

Operation indicator 
(orange)

Receiver only.

Lit when the output is ON.

No.

Part

Description

1

Beam axis

2

Stability indicator 
(green)

Receiver only.

Lit when detection is stable according 
to the parameters set.

3

Operation indicator 
(orange)

Receiver only.

Lit when the output is ON.

4

Operation mode 
switch

Receiver only.

• L: Light-ON

Turn the operation mode 
switch fully clockwise until it 
stops.

• D: Dark-ON

Turn the operation mode 
switch fully 
counterclockwise until it 
stops.

5

Sensitivity adjuster

Emitter only.

Sensing range increased when turned 
clockwise.
See “SENSITIVITY ADJUSTMENT” on 
page 2.

1

2 3

L

D

1

2

3

4

5

L

D

L

D