375
Memory Cassette Functions
Section 6-6
Data that Can be
Stored on a Memory
Cassette
The following data can be stored on a Memory Cassette.
The areas for storing various types of data have fixed allocations in the Mem-
ory Cassette, and a single Memory Cassette corresponds to a single CPU
Unit.
Therefore it is not possible to simultaneously store multiple items of the same
type of data (e.g., two user programs).
Also, the data can only be read to a CPU Unit. It cannot be directly managed
from a personal computer like files.
The only data that can be stored on a Memory Cassette is the data from a
CPU Unit.
Note
The CX-Programmer's function for saving DM initial values is used for saving
the values in the DM Area (D0 to D32767) to the built-in flash memory as ini-
tial values. By means of a setting in the PLC Setup, these initial values can
then be automatically written to the DM Area (D0 to D32767) when the power
is turned ON.
6-6-2
Mounting and Removing a Memory Cassette
Mounting
1,2,3...
1.
Turn OFF the power supply to the PLC and removed the cover to the Mem-
ory Cassette socket.
Data stored on Memory Cassette
Location in CPU Unit
User programs
Built-in RAM, built-in flash
memory (User Program Area)
Parameters
PLC Setup, CPU Bus Unit set-
tings, routing tables
Built-in RAM, built-in flash
memory (Parameter Area)
Comment data
for user pro-
grams
Variable tables
Built-in flash memory (Com-
ment Memory Area)
(I/O comments, rung com-
ments, program comments)
Built-in flash memory (Com-
ment Memory Area)
Program indexes (section
names, section comments,
program comments)
Built-in flash memory (Com-
ment Memory Area)
Function Block (FB) sources
Built-in flash memory (FB
Source Memory Area)
DM
Built-in RAM (D0 to D32767 in
DM Area)
DM initial values (See note.)
Built-in flash memory (DM Ini-
tial Values Area)
CPU Units with 14 or 20 I/O Points
CPU Units with 30 or 40 I/O Points
Summary of Contents for CP1L-L14D Series
Page 2: ...CP1L L14D CP1L L20D CP1L M30D CP1L M40D CP1L CPU Unit Operation Manual Revised June 2007...
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 153: ...120 CP CPM1A series Expansion I O Unit Wiring Section 3 6...
Page 523: ...490 Troubleshooting Unit Errors Section 9 4...
Page 531: ...498 Replacing User serviceable Parts Section 10 2...
Page 563: ...530 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...578 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...605 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...606 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...636 Index...
Page 671: ...638 Revision History...