250
Pulse Outputs
Section 5-2
■
DM Area Settings
Starting Frequency
PLS2(887) Settings to Move from Origin to Position A
PLS2(887) Settings to Move from Position A to Position B
Setting details
Address
Data
X-axis starting frequency
D0
0000
Y-axis starting frequency
D2
0000
Setting details
Address
Data
X axis
Acceleration rate: 2,000 Hz/4 ms
D10
07D0
Deceleration rate: 2,000 Hz/4 ms
D11
07D0
Target frequency: 100,000 Hz
D12
86A0
D13
0001
Number of output pulses: 5,000 pulses
D14
1388
D15
0000
Y axis
Acceleration rate: 2,000 Hz/4 ms
D20
07D0
Deceleration rate: 2,000 Hz/4 ms
D21
07D0
Target frequency: 100,000 Hz
D22
86A0
D23
0001
Number of output pulses: 5,000 pulses
D24
1388
D25
0000
Setting details
Address
Data
X axis
Acceleration rate: 2,000 Hz/4 ms
D30
07D0
Deceleration rate: 2,000 Hz/4 ms
D31
07D0
Target frequency: 100,000 Hz
D32
86A0
D33
0001
Number of output pulses: 25,000 pulses
D34
61A8
D35
0000
Summary of Contents for CP1L-L14D Series
Page 2: ...CP1L L14D CP1L L20D CP1L M30D CP1L M40D CP1L CPU Unit Operation Manual Revised June 2007...
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 153: ...120 CP CPM1A series Expansion I O Unit Wiring Section 3 6...
Page 523: ...490 Troubleshooting Unit Errors Section 9 4...
Page 531: ...498 Replacing User serviceable Parts Section 10 2...
Page 563: ...530 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...578 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...605 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...606 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...636 Index...
Page 671: ...638 Revision History...