177
Pulse Outputs
Section 5-2
Pulse Frequency Conversion
The pulse frequency input to a high-speed counter can be converted to a rota-
tional speed (r/min) or the PV of the counter can be converted to the total
number of rotations. The converted value is output as 8-digit hexadecimal.
This function is supported only for high-speed counter 0.
Frequency
−
Rotational Speed Conversion
The rotational speed in r/min is calculated from the pulse frequency input to a
high-speed counter and the number of pulses per rotation.
Counter PV
−
Total Number of Rotations Conversion
The total number of rotations is calculated from the present value of the
counter and the number of pulses per rotation.
Procedure
1,2,3...
1.
High-speed Counter Enable/Disable Setting (Required)
Select the
Use high speed counter 0
Option in the PLC Setup.
2.
Pulse Input Mode Setting (Required)
Set the High-speed Counter 0 Pulse Input Mode (
Input Setting
) in the PLC
Setup.
3.
Counting Mode Setting (Required)
Set the High-speed Counter 0
Counting Mode
in the PLC Setup.
If ring mode counting is selected, set the
Circular Max. Count
(max. ring
count) in the PLC Setup.
4.
Reset Method Setting (Required)
Set the High-speed Counter 0 Reset Method in the PLC Setup.
5.
Execute PRV2(883) as described below (required).
Converting the Frequency to a Rotational Speed
Execute PRV2(883) with the following operands.
C: Control data (Set to 0000 for frequency-rotational speed conversion.)
P: Coefficient (pulses/rotation (hex))
D: First word for result
Converting the Counter PV to the Total Number of Rotations
Execute PRV2(883) with the following operands.
C: Control data (Set to 0001 for counter PV-total number of rotations con-
version.)
P: Coefficient (pulses/rotation (hex))
D: First word for result
Restrictions
Pulse frequency conversion is possible only for high-speed counter 0.
5-2
Pulse Outputs
5-2-1
Overview
Fixed duty factor pulses can be output from the CPU Unit's built-in outputs to
perform positioning or speed control with a servo driver that accepts pulse
inputs.
■
CW/CCW Pulse Outputs or Pulse + Direction Outputs
The pulse output mode can be set to match the motor driver's pulse input
specifications.
Summary of Contents for CP1L-L14D Series
Page 2: ...CP1L L14D CP1L L20D CP1L M30D CP1L M40D CP1L CPU Unit Operation Manual Revised June 2007...
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 153: ...120 CP CPM1A series Expansion I O Unit Wiring Section 3 6...
Page 523: ...490 Troubleshooting Unit Errors Section 9 4...
Page 531: ...498 Replacing User serviceable Parts Section 10 2...
Page 563: ...530 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...578 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...605 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...606 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...636 Index...
Page 671: ...638 Revision History...