562
Auxiliary Area Allocations by Address
Appendix D
A508
A508.09 Differentiate
Monitor
Completed
Flag
ON when the differentiate monitor
condition has been established dur-
ing execution of differentiation moni-
toring.
(This flag will be cleared to 0 when
differentiation monitoring starts.)
ON: Monitor
condition
established
OFF: Not yet
established
Retained
Cleared
---
---
A508.11 Trace Trig-
ger Monitor
Flag
ON when a trigger condition is estab-
lished by the Trace Start Bit
(A508.14). OFF when the next Data
Trace is started by the Sampling
Start bit (A508.15).
ON: Trigger
condition
established
OFF: Not yet
established or
not tracing
Retained
Cleared
---
---
A508.12 Trace Com-
pleted Flag
ON when sampling of a region of
trace memory has been completed
during execution of a Trace.
OFF when the next time the Sam-
pling Start Bit (A508.15) is turned
ON.
ON: Trace
completed
OFF: Not trac-
ing or trace in
progress
Retained
Cleared
---
---
A508.13 Trace Busy
Flag
ON when the Sampling Start Bit
(A508.15) is turned ON. OFF when
the trace is completed.
ON: Trace in
progress
OFF: Not trac-
ing (not sam-
pling)
Retained
Cleared
---
---
A508.14 Trace Start
Bit
Turn this bit ON to establish the trig-
ger condition. The offset indicated by
the delay value (positive or negative)
determines which data samples are
valid.
ON: Trace trig-
ger condition
established
OFF: Not
established
Retained
Cleared
---
---
A508.15 Sampling
Start Bit
When a data trace is started by turn-
ing this bit ON from the CX-Program-
mer, the PLC will begin storing data
in Trace Memory by one of the three
following methods:
1) Data is sampled at regular inter-
vals (10 to 2,550 ms).
2) Data is sampled when TRSM(045)
is executed in the program.
3) Data is sampled at the end of
every cycle.
The operation of A508.15 can be
controlled only from the CX-Pro-
grammer.
OFF to ON:
Starts data
trace (sam-
pling)
Turned ON
from Program-
ming Device.
Retained
Cleared
---
---
A510 to
A511
All
startup Time These words contain the time at
which the power was turned ON. The
contents are updated every time that
the power is turned ON. The data is
stored in BCD.
A510.00 to A510.07: Second (00 to
59)
A510.08 to A510.15: Minute (00 to
59)
A511.00 to A511.07: Hour (00 to 23)
A511.08 to A511.15: Day of month
(01 to 31)
See Function
column.
Retained
See
Function
column.
Refresh-
ed when
power is
turned
ON.
---
A512 to
A513
All
Power Inter-
ruption Time
These words contain the time at
which the power was interrupted.
The contents are updated every time
that the power is interrupted. The
data is stored in BCD.
A512.00 to A512.07: Second (00 to
59)
A512.08 to A512.15: Minute (00 to
59)
A513.00 to A513.07: Hour (00 to 23)
A513.08 to A513.15: Day of month
(01 to 31)
(These words are not cleared at star-
tup.)
See Function
column.
Retained
Retained
Written at
power
interrup-
tion
---
Addresses
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
Flags,
Settings
Word
Bits
Summary of Contents for CP1L-L14D Series
Page 2: ...CP1L L14D CP1L L20D CP1L M30D CP1L M40D CP1L CPU Unit Operation Manual Revised June 2007...
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 153: ...120 CP CPM1A series Expansion I O Unit Wiring Section 3 6...
Page 523: ...490 Troubleshooting Unit Errors Section 9 4...
Page 531: ...498 Replacing User serviceable Parts Section 10 2...
Page 563: ...530 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...578 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...605 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...606 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...636 Index...
Page 671: ...638 Revision History...