573
Auxiliary Area Allocations by Address
Appendix D
Note
The following flags are provided in a special read-only area and can be specified with the labels given in
the table. These flags are not contained in the Auxiliary Area. Refer to
4-14 Condition Flags
and
4-15
Clock Pulses
for details.
Flag area
Name
Label
Meaning
Condition Code
Area
Error Flag
ER
Turns ON when an error occurs in processing an instructions, indi-
cating an error end to the instruction.
Access Error Flag
AER
Turns ON when an attempt is made to access an illegal area. The
status of this flag is maintain only during the current cycle and only
in the task in which it occurred.
Carry Flag
CY
Turns ON when there is a carry or borrow in a math operation,
when a bit is shifted into the Carry Flag, etc.
Greater Than Flag
>
Turns ON when the result of comparing two values is
“
greater
than,
”
when a value exceeds a specified range, etc.
Equals Flag
=
Turns ON when the result of comparing two values is
“
equals,
”
when the result of a math operation is 0, etc.
Less Than Flag
<
Turns ON when the result of comparing two values is
“
less than,
”
when a value is below a specified range, etc.
Negative Flag
N
Turns ON when the MSB in the result of a math operation is 1.
Overflow Flag
OF
Turns ON when the result of a math operation overflows.
Underflow Flag
UF
Turns ON when the result of a math operation underflows.
Greater Than or Equals
Flag
>=
Turns ON when the result of comparing two values is
“
greater than
or equals.
”
Not Equal Flag
<>
Turns ON when the result of comparing two values is
“
not equal.
”
Less than or Equals Flag
<=
Turns ON when the result of comparing two values is
“
less than or
equals.
”
Always ON Flag
A1
This flag is always ON.
Always OFF Flag
A0
This flag is always OFF.
Clock Pulse
Area
0.02-s clock pulse
0.02s
Repeatedly turns ON for 0.02 s and OFF for 0.02 s.
0.1-s clock pulse
0.1s
Repeatedly turns ON for 0.1 s and OFF for 0.1 s.
0.2-s clock pulse
0.2s
Repeatedly turns ON for 0.2 s and OFF for 0.2 s.
1-s clock pulse
1s
Repeatedly turns ON for 1 s and OFF for 1 s.
1-min clock pulse
1min
Repeatedly turns ON for 1 min and OFF for 1 min.
Summary of Contents for CP1L-L14D Series
Page 2: ...CP1L L14D CP1L L20D CP1L M30D CP1L M40D CP1L CPU Unit Operation Manual Revised June 2007...
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 153: ...120 CP CPM1A series Expansion I O Unit Wiring Section 3 6...
Page 523: ...490 Troubleshooting Unit Errors Section 9 4...
Page 531: ...498 Replacing User serviceable Parts Section 10 2...
Page 563: ...530 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...578 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...605 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...606 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...636 Index...
Page 671: ...638 Revision History...