273
Inverter Positioning
Section 5-3
ORIGIN SEARCH:
ORG(889)
ORG(889) performs an origin search or origin return operation.
• Origin Search:
Pulses are output to establish the origin based on origin proximity input
and origin input signals.
• Origin Return:
The positioning system is returned to the origin.
The parameters for pulse output 0 or pulse output 1 must be set in advance in
the PLC Setup to perform either an origin search or origin return operation.
MODE CONTROL: INI(880)
INI(880) changes the present value of inverter positioning or stops position-
ing.
F
First word of
starting fre-
quency
F (lower 4 dig-
its)
Starting Frequency in Hz
Pulse output 0 or 1: 0000 0000 to 0001 86A0
hex (0 to 100 kHz)
F+1 (upper 4
digits)
Operand
Description
Operand
Description
P
Port specifier
0020 hex: Inverter positioning 0
0021 hex: Inverter positioning 1
C
Control data
Bits 0 to 3
Not used: Always set to 0 hex
Bits 4 to 7
Not used: Always set to 0 hex
Bits 8 to 11
Not used: Always set to 0 hex
Bits 9 to 15
Mode
0 hex: Origin search
1 hex: Origin return
ORG(889)
P
C
C: Control data
P: Port specifier
Operand
Description
P
Port specifier
0020 hex: Inverter positioning 0
0021 hex: Inverter positioning 1
C
Control data
0002 hex: Changes the PV of the internal pulse
output.
0003 hex: Stops internal pulse output. Position-
ing will continue and the output value will not be
cleared.
0004 hex: Stops inverter positioning. Internal
pulse output will be stopped, positioning will be
stopped, and the output value will be cleared.
The next operation will not be accepted until the
error counter is cleared.
NP First word
with new PV
NP (lower 4
digits)
New PV
0000 0000 to FFFF FFFF hex
NP+1 (upper
4 digits)
INI(880)
C: Control data
P: Port specifier
NV: First word with new PV
P
C
NP
Summary of Contents for CP1L-L14D Series
Page 2: ...CP1L L14D CP1L L20D CP1L M30D CP1L M40D CP1L CPU Unit Operation Manual Revised June 2007...
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 153: ...120 CP CPM1A series Expansion I O Unit Wiring Section 3 6...
Page 523: ...490 Troubleshooting Unit Errors Section 9 4...
Page 531: ...498 Replacing User serviceable Parts Section 10 2...
Page 563: ...530 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...578 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...605 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...606 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...636 Index...
Page 671: ...638 Revision History...