Operation with the Touch Panel
LMV1000 (G)(E) AIR-COOLED LASER MARKER
6-16
990-541
For example; if 5 characters are defined for marking, but only the second, third and fifth have
LD values associated with them and 20.0A is defined on the
System set
screen, the marking
process would occur as follows:
Line No.
Setting
Current Actually Used
1 --.-
20.0 A
2 25.0
25.0 A
3 30.0
30.0 A
4 --.-
30.0 A
5 25.0
25.0 A
4. Layout (Arc) Screen
NOTE:
The functions of these buttons are the same as the
Layout (Straight Line
) Screen.
a.
Line No
Indicates the line number selected by the
Last
and
Next
buttons.
b. Line
Switches to the
Layout (Straight line)
screen.