7: OPERATION WITH A PC
LMV1000 (G)(E) AIR-COOLED LASER MARKER
7-26
990-541
Edge control
Item
Description
OFF
Does not perform edge control.
Run-up mode
Performs edge control.
Edge control
Accelerator mode
Adjusts the start/end point distance for edge control
automatically (Note: the marking speed must be 1000mm/s or
greater).
Start point adjusting
distance
Sets the scanner distance before the starting point.
End point adjusting
distance
Sets the scanner distance after the end point.
Effective crossed
axes angle
Sets the maximum crossed axes angle.
Accelerator
coefficient 1
Sets the scanner optimization coefficient for pre/post marking.
Control
distance/angle
Accelerator
coefficient 2
Sets the scanner radius of curve marking speed coefficient.
Automatic
intersection removal
When a thick line is marked, the intersection removal margin is
automatically implemented.
Intersection
removal
Removal margin
Sets the manually defined intersection removal margin when a
thick line is marked.