Operation with the Touch Panel
LMV1000 (G)(E) AIR-COOLED LASER MARKER
6-10
990-541
c. Y
axis
Used to set the absolute origin in the Y-axis direction.
d.
ș
axis
Used to set the angle of the absolute origin in the counterclockwise direction.
6. Jump / Shutter Screen
Sets the jump timing for opening / closing the
shutter. The term “Jump” defines how the laser
moves from the end point of one object mark to
the start point of the next object.
a.
Safety shutter control
INTRLOCK
The safety shutter is controlled by the marking start signal.
Firm OP
The safety shutter is always open when the LD is turned on.
b. Jump
speed
Defines how fast the mirrors change position from the end point of one character to the starting
point of the next character.
c.
Wait after Jump
Sets the marking wait time after a jump.
d.
Open DLY Time
Defines when the laser output begins after the jump wait period.
e.
Close DLY Time
Defines when the laser output ends after a mark.
Summary of Contents for LMV1000
Page 8: ...LMV1000 G E AIR COOLED LASER MARKER viii 990 541...
Page 9: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 ix...
Page 17: ......
Page 35: ......
Page 47: ......
Page 215: ...8 COMMUNICATION FUNCTION OPTION LMV1000 G E AIR COOLED LASER MARKER 8 14 990 541...
Page 231: ......
Page 237: ......
Page 239: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 2 990 541 Oscillator Continued...
Page 241: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 4 990 541 Oscillator 1 2 3 4...
Page 243: ......
Page 259: ......