8: COMMUNICATION FUNCTION (OPTION)
LMV1000 (G)(E) AIR-COOLED LASER MARKER
990-541
8-13
g.
ACR/ACW (Consumables operating time)
Read the cumulative operating hours of the LD.
Initialize (Set) the cumulative operating hours when the LD is replaced.
i.
Read (ACR)
ii.
Write (ACW t0,t1)
Execute this command when replacing the LD, and set the LD wavelength and the LD current
limit.
t0: LD wavelength (0.1nm increment)
t1: LD current limit (0.1A increment)
16.
BAR/BAW (Transmission conditions)
Read and Write the communication conditions.
a. Read
(BAR)
PC
ψ
Marker : BAR
Marker
ψ
PC : s0,s1,s2,s3,s4
s0
Baud rate
0: 4800, 1: 9600, 2: 19200, 3: 38400, 4: 57600, 5: 115200 bps
s1
Stop bit
0: 1 bit, 1: 2 bit
s2
Parity
0: None, 2: Even, 3:Odd
s3
Checksum
0: OFF, 1: ON
s4
Delimiter ETX
0: OFF, 1: ON
b. Write
(BAW
t0,t1,t2,t3)
Example
When the LD operating hour is 1 hour:
PC
ψ
Marker : ACR
Marker
ψ
PC : 3600 (Unit: 1 second)
Example
When setting LD wavelength to 808.9nm; LD current limit, 35A:
Marker
ψ
PC : ACW8089,350
Example
When the conditions are 9600bps, Stop bit, Even parity and No checksum (initial settings):
PC
ψ
Marker : BAW,1,0,2,0
Except for checksum, these conditions become valid when the Marker is restarted.
Summary of Contents for LMV1000
Page 8: ...LMV1000 G E AIR COOLED LASER MARKER viii 990 541...
Page 9: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 ix...
Page 17: ......
Page 35: ......
Page 47: ......
Page 215: ...8 COMMUNICATION FUNCTION OPTION LMV1000 G E AIR COOLED LASER MARKER 8 14 990 541...
Page 231: ......
Page 237: ......
Page 239: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 2 990 541 Oscillator Continued...
Page 241: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 4 990 541 Oscillator 1 2 3 4...
Page 243: ......
Page 259: ......