CHAPTER 12: MAINTENANCE
LMV1000 (G)(E) AIR-COOLED LASER MARKER
990-541
12-7
8.
Hold the LD - I/O connector and pull it
out horizontally.
9.
Loosen the four Phillips-head screws
on the optical fiber fixture on the rear
of the Control Unit to remove the
optical fiber.
10.
Turn the fastening nut of the optical
fiber CCW (counter-clockwise) with an
8mm wrench as shown on the right.
Slowly pull out the optical fiber.
Immediately place a dust-proof cap on
the fiber to prevent dust from collecting
on the fiber end face.
CAUTION: Never
bend the optical
fiber more than the minimum bend
radius of 5.9” (150mm) or you may
damage the fiber.
11.
Remove the four, 3mm hex screws that fasten the LD Module to the Control Unit. Leave the
graphite sheet (placed between the heat sink and the LD module) inside the Control Unit. If the
graphite sheet is cracked or creased, replace it. The graphite sheet is used to transfer heat from
the LD module to the Peltier Cooling device.
12.
Install the new LD Module into the Control Unit onto the graphite sheet. Fasten the LD module
with the four hex screws.
Summary of Contents for LMV1000
Page 8: ...LMV1000 G E AIR COOLED LASER MARKER viii 990 541...
Page 9: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 ix...
Page 17: ......
Page 35: ......
Page 47: ......
Page 215: ...8 COMMUNICATION FUNCTION OPTION LMV1000 G E AIR COOLED LASER MARKER 8 14 990 541...
Page 231: ......
Page 237: ......
Page 239: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 2 990 541 Oscillator Continued...
Page 241: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 4 990 541 Oscillator 1 2 3 4...
Page 243: ......
Page 259: ......