CHAPTER 13: TROUBLESHOOTING
LMV1000 (G)(E) AIR-COOLED LASER MARKER
13-2
990-541
Error
Code
Problem LD
1
Cause/Corrective
Action
30
LD Power Supply Overheat Error.
OFF
The LD Power Supply is overheating. The possible causes for
this error are:
Dirty Control Unit Air-filter, clean as necessary.
High Ambient temperature,
t
95
q
F (~35
q
C)
Perform corrective action, and then wait at least 10 minutes
before re-starting the Marker. If this error persists, contact
Miyachi America.
31
LD Current Error
OFF
An LD current error has been detected. This error occurs
when the measured current doesn’t match the power supply
set value. This error can occur when A.C. line transients are
present. Recycle the power on the Marker. If this error
persists, contact Miyachi America.
32
LD Voltage Error
OFF
An LD voltage error has been detected. This error occurs
when the measured voltage doesn’t match the power supply
set value. This error can occur when A.C. line transients are
present. Recycle the power on the Marker. If this error
persists, contact Miyachi America.
33
LD Peltier Power Supply Overheat
Error
OFF
The Peltier Power Supply used to cool the LD module is
overheating. The possible causes for this error are:
Dirty Control Unit Air-filter, clean as necessary.
High Ambient temperature,
t
95
q
F (~35
q
C)
Perform corrective action, and then wait at least 10 minutes
before re-starting the Marker. If this error persists, contact
Miyachi America.
34
Crystal Peltier Power Supply
Overheat Error
OFF
The Peltier Power Supply used to cool the Nd:YVO
4
crystal is
overheating. The possible causes for this error are:
Dirty Control Unit Air-filter, clean as necessary.
High Ambient temperature,
t
95
q
F (~35
q
C)
Perform corrective action, and then wait at least 10 minutes
before re-starting the Marker. If this error persists, contact
Miyachi America.
40
RF Power progressive waveform
poor
OFF
The quality of the RF Unit waveform that supplies power to
the Q-Switch is poor. The possible causes for this error are:
Poor RF cable connection, check cable connection.
Faulty RF Power Unit
Faulty Q-Switch
Recycle the power on the Marker. If this error persists, contact
Miyachi America.
41
RF Power progressive waveform
excessive
OFF
The output power of the RF Unit is excessive. The possible
causes for this error are:
Poor RF cable connection, check cable connection.
Faulty RF Power Unit
Faulty Q-Switch
Recycle the power on the Marker. If this error persists, contact
Miyachi America.
Summary of Contents for LMV1000
Page 8: ...LMV1000 G E AIR COOLED LASER MARKER viii 990 541...
Page 9: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 ix...
Page 17: ......
Page 35: ......
Page 47: ......
Page 215: ...8 COMMUNICATION FUNCTION OPTION LMV1000 G E AIR COOLED LASER MARKER 8 14 990 541...
Page 231: ......
Page 237: ......
Page 239: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 2 990 541 Oscillator Continued...
Page 241: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 4 990 541 Oscillator 1 2 3 4...
Page 243: ......
Page 259: ......