7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 5
(2) Parameter
Select how to set the filter tuning in [Pr. PB01 Adaptive tuning mode (adaptive filter II)].
[Pr. PB01]
Filter tuning mode selection
0 0
0
1
2
Setting
value
Filter tuning mode selection
Disabled
Automatic setting
Manual setting
PB13/PB14
Automatically set parameter
Tuning accuracy selection (Note)
0: Standard
1: High accuracy
Note. This digit is available with servo amplifier with software version C5 or later.