11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 20
11.7 Power factor improving AC reactor
The following shows the advantages of using power factor improving AC reactor.
It improves the power factor by increasing the form factor of the servo amplifier's input current.
It decreases the power supply capacity.
The input power factor is improved to about 80%.
When using power factor improving reactors for two servo amplifiers or more, be sure to connect a power
factor improving reactor to each servo amplifier. If using only one power factor improving reactor, enough
improvement effect of phase factor cannot be obtained unless all servo amplifiers are operated.
(1) Connection example
(a) When using 3-phase 200 V AC to 240 V AC power supply
Y
Z
S
T
MC
MCCB
FR-HAL
Servo amplifier
X
R
L1
L2
L3
3-phase
200 V AC to
240 V AC
(b) When using 1-phase 200 V AC to 240 V AC power supply for MR-JE-10A to MR-JE-100A
Y
Z
S
T
MC
MCCB
FR-HAL
Servo amplifier
X
R
L1
L2
(Note)
1-phase
200 V AC to
240 V AC
L3
Note. Connect the power supply to L1 and L3. Leave L2 open.
(c) When using 1-phase 200 V AC to 240 V AC power supply for MR-JE-200A
Y
Z
S
T
MC
MCCB
FR-HAL
Servo amplifier
X
R
L1
L2
L3
(Note)
1-phase
200 V AC to
240 V AC
Note. Connect the power supply to L1 and L2. Leave L3 open.
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...