12. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)
12 - 24
(5) Reading external output pin status
The following shows how to read the on/off status of the external output pins.
(a) Transmission
Transmit command [1] [2] and data No. [C] [0].
Command Data
No.
[1] [2]
[C] [0]
(b) Return
The slave station returns the status of the output devices.
b31
b1b0
1: On
0: Off
Command of each bit is transmitted to the master station as hexadecimal data.
Bit
CN1 connector pin
Bit
CN1 connector pin
Bit
CN1 connector pin
Bit
CN1 connector pin
0 49
8
16
24
1 24
9
17
25
2
23
10
18
26
3
11
19
27
4
12
20
28
5
48
13
21
29
6
33
14
22
30
7
15
23
31