5. PARAMETERS
5 - 12
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control mode
P S T
PA09
RSP
Auto tuning
response
Set a response of the auto tuning.
16
Setting
value
Machine characteristic
Setting
value
Machine characteristic
Response
Guideline for
machine
resonance
frequency [Hz]
Response
Guideline for
machine
resonance
frequency [Hz]
1
Low
respon
se
2.7
21
Middle
respon
se
67.1
2
3.6
22
75.6
3
4.9
23
85.2
4
6.6
24
95.9
5
10.0
25
108.0
6
11.3
26
121.7
7
12.7
27
137.1
8
14.3
28
154.4
9
16.1
29
173.9
10
18.1
30
195.9
11
20.4
31
220.6
12
23.0
32
248.5
13
25.9
33
279.9
14
29.2
34
315.3
15
32.9
35
355.1
16
37.0
36
400.0
17
41.7
37
446.6
18
47.0
38
501.2
19
52.9
39
571.5
20
Middle
respon
se
59.6
40
High
respon
se
642.7
Setting range: 1 to 40
PA10
INP
In-position
range
Set an in-position range per command pulse.
To change it to the servo motor encoder pulse unit, set [Pr. PC24].
Setting range: 0 to 65535
100
[pulse]
PA11
TLP
Forward
rotation
torque limit
You can limit the torque generated by the servo motor. Set the parameter referring to
section 3.6.1 (5).
The larger value of [Pr. PA11 Forward rotation torque limit] or [Pr. PA12 Reverse
rotation torque limit] will be the maximum output voltage (8 V).
Set the parameter on the assumption that the maximum torque is 100 [%]. The
parameter is for limiting the torque of the servo motor in the CCW power running or
CW regeneration. Set this parameter to "0.0" to generate no torque.
Setting range: 0.0 to 100.0
100.0
[%]
PA12
TLN
Reverse
rotation
torque limit
You can limit the torque generated by the servo motor. Set the parameter referring to
section 3.6.1 (5).
The larger value of [Pr. PA11 Forward rotation torque limit] or [Pr. PA12 Reverse
rotation torque limit] will be the maximum output voltage (8 V).
Set the parameter on the assumption that the maximum torque is 100 [%]. The
parameter is for limiting the torque of the servo motor in the CW power running or
CCW regeneration. Set this parameter to "0.0" to generate no torque.
Setting range: 0.0 to 100.0
100.0
[%]
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...