3. SIGNALS AND WIRING
3 - 33
The following section explains about the case where the negative logic and the forward/reverse
rotation pulse trains are set to "_ _ 1 0" in [Pr. PA13].
Reverse rotation command
Forward rotation command
(OFF)
(OFF)
(OFF)
(ON)
(ON)
(ON) (OFF) (ON) (OFF) (ON)
(OFF)
Forward rotation pulse train
(transistor)
Reverse rotation pulse train
(transistor)
(ON)
2) Differential line driver type
Connect as follows.
PP
NP
Servo amplifier
PG
NG
SD
Approximately
100
Ω
Approximately
100
Ω
(Note)
Note. Pulse train input interface is comprised of a photocoupler.
If a resistor is connected to the pulse train signal line, it may malfunction due to
reduction in current.
The following example shows that an input waveform has been set to the negative logic and
forward/reverse rotation pulse trains by setting "_ _ 1 0" in [Pr. PA13]. The waveforms of PP, PG,
NP, and NG are based on LG.
Reverse rotation
PP
PG
NP
NG
Reverse rotation
pulse train
Forward rotation
pulse train
Forward rotation