7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 20
(2) When you choose switching by droop pulses
The vibration suppression control after gain switching and model loop gain after gain switching cannot
be used.
(a) Setting
Parameter Symbol
Name
Setting
value
Unit
PB06
GD2
Load to motor inertia ratio
4.00
[Multiplier]
PB08
PG2
Position loop gain
120
[rad/s]
PB09
VG2
Speed loop gain
3000
[rad/s]
PB10
VIC
Speed integral compensation
20
[ms]
PB29
GD2B
Load to motor inertia ratio after
gain switching
10.00 [Multiplier]
PB30 PG2B
Position
loop gain after gain
switching
84 [rad/s]
PB31
VG2B
Speed loop gain after gain
switching
4000 [rad/s]
PB32
VICB
Speed integral compensation after
gain switching
50 [ms]
PB26
CDP
Gain switching function
0003
(switching by droop pulses)
PB27
CDL
Gain switching condition
50
[pulse]
PB28
CDT
Gain switching time constant
100
[ms]
(b) Switching timing chart
After-switching gain
63.4%
CDT = 100 ms
Before-switching gain
Gain switching
Droop pulses
[pulse]
+CDL
-CDL
0
Command pulses
Droop pulses
Command pulses
Load to motor inertia ratio
4.00
→
10.00
→
4.00
→
10.00
Position loop gain
120
→
84
→
120
→
84
Speed loop gain
3000
→
4000
→
3000
→
4000
Speed integral compensation
20
→
50
→
20
→
50
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...