12. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)
12 - 18
12.5.3 Parameter
(1) Specification of the parameter group
To read or write the parameter settings, etc., the group of the parameters to be operated must be
specified in advance. Write data to the servo amplifier as follows to specify the parameter group.
Command Data
No.
Transmission
data
Parameter group
[8] [5]
[0] [0]
0000
Basic setting parameters ([Pr. PA_ _ ])
0001
Gain/filter parameters ([Pr. PB_ _ ])
0002
Extension setting parameters ([Pr. PC_ _ ])
0003
I/O setting parameters ([Pr. PD_ _ ])
0004
Extension setting 2 parameters ([Pr. PE_ _ ])
0005
Extension setting 3 parameters ([Pr. PF_ _ ])
(2) Parameter group reading
The following shows how to read the parameter group set with slave station.
(a) Transmission
Transmit command [0] [4] and data No. [0] [1].
Command Data
No.
[0] [4]
[0] [1]
(b) Return
The slave station returns the preset parameter group.
0
0
Parameter group
0: Basic setting parameters ([Pr. PA_ _ ])
1: Gain/filter parameters ([Pr. PB_ _ ])
2: Extension setting parameters ([Pr. PC_ _ ])
3: I/O setting parameters ([Pr. PD_ _ ])
4: Extension setting 2 parameters ([Pr. PE_ _ ])
5: Extension setting 3 parameters ([Pr. PF_ _ ])
0
(3) Reading symbols
The following shows how to read symbols of parameters. Specify a parameter group in advance. (Refer
to (1) in this section.)
(a) Transmission
Transmit the command [0] [8] and the data No. [0] [1] to [F] [F] corresponding to the parameter No.
(Refer to section 12.4.1.)
The data No. is expressed in hexadecimal. The decimal equivalent of the data No. value
corresponds to the parameter No.
(b) Return
The slave station returns the symbol of the parameter requested.
0 0 0
Symbol characters (9 digits)
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...